Enterprise server power and continuity management with no physical intervention and zero cable clutter.

Having to send a technician to the data center whenever a server's operating system locks up, hits a kernel panic or shows a blue screen multiplies maintenance costs and service downtime. Equlon SR USB-O2 is an OS-independent, hardware-based out-of-band (OOB) management solution that plugs directly into the server motherboard's internal 9-pin USB 2.0 header.
Even when your server is completely frozen, you can remotely trigger its Reset and Power buttons at the hardware level and bring the system back up in seconds.
An X7R dielectric ceramic capacitor design, industrial-grade semiconductors and the high-temperature ESP32-C3-MINI-1-H4X SoC withstand harsh in-cabinet temperatures without compromise.
No need to run an extra cable to the front-panel Power LED header. The ESP32-C3 analyzes host controller activity and suspend states over the internal USB data lines (D+/D-) to determine at hardware level whether the server is on (S0) or off/standby (S5).
The motherboard's front-panel Reset and Power lines are protected by industrial optocouplers and 2N7002 open-drain MOSFET drivers. Ground loops, leakage currents and electrical noise between the server and the control module are completely blocked.
To overcome the Faraday cage effect of server chassis, modules communicate with each other in a wireless mesh topology (hop-by-hop), providing lossless access to the gateway through the module closest to the outside of the cabinet.
Its slim design fits directly inside 1U and 2U blade and rack servers without touching adjacent RAM slots or PCIe riser cards.
The module enclosure and PCB layer fully comply with the UL94-V0 self-extinguishing flame-retardant rating that enterprise data centers require.
When the on-board hardware maintenance jumper is shorted, all trigger commands, whether remote or from the automatic software watchdog, are locked out, keeping field technicians physically safe while they work.
When a new MQTT broker is configured remotely, the module tests the connection and automatically falls back to the last working address if the link drops. On isolated sites without internet access, devices can be configured in bulk with a single UDP broadcast.
Instant remote power cycling for rented servers, eliminating emergency site visits and "remote hands" costs.
Autonomous lock-up recovery for industrial PCs running in factories, highway control cabinets or base stations.
Direct intervention from a mobile or web interface when critical ERP, CRM or database servers freeze outside business hours.
Programmatic reboots and power management of physical server nodes in automated test pipelines.
Turns service calls and on-site interventions that can take hours into a 5-second remote command.
Delivers independent per-server power control without expensive, space-consuming switched PDU infrastructure.
Open the chassis, plug it straight into the internal USB header and have it configured within 2 minutes.
Let's talk about Equlon SR USB-O2 for your data center, server room or edge sites. Our team will get in touch to walk you through the details.
Contact Us